Rigid Steel Conduit Specifications

Bundles for steel rigid metal conduit intermediate metal conduit imc and electrical metallic tubing emt.
Rigid steel conduit specifications. Electrical rigid steel conduit ansi c80 1 this standard ansi c80 1 covers the requirements for electrical rigid steel conduit for use as a raceway for wires or cables of an electrical system. To specify rigid steel conduit and kwik couple rigid steel. Pack quantities for canadian distribution do not comply with nema rn 2. Threads shall be hot galvanized after cutting.
Calconduit rigid conduit is manufactured in accordance with the latest edition of the following. The length is nominal and subject to the tolerance of ul standard for safety for electrical rigid metal conduit steel ul 6. Our steel rigid metal conduit provides protection from severe physical damage the highest level. Threads shall be hot galvanized after cutting.
It shall be manu factured in accordance with ansi c80 1. The pitch of rigid metal conduit threads conforms to the american national standard for pipe threads general purpose inch ansi asme b1 20 1. Rigid steel conduit shall be hot dip galvanized and manufactured by allied tube conduit. Our rigid aluminum conduit is made from marine grade 6063 aluminum alloy t 1 temper delivering exceptional strength and corrosion resistance and the lightweight design allows for easy installation.
It shall be manufactured in accordance with ansi c80 1. American national standards institute ansi american national standard for rigid steel tubing ansi c80 1 underwriters laboratories standard for rigid steel tubing ul6 national electric code 2002 article 344. Rigid steel conduit shall be listed to ul safety standard 6 by a nationally recognized testing laboratory with follow up service. Galvanized rigid steel conduit grc rmc is the heaviest weight and thickest wall of electrical conduits.
Conduit include the following. Finished conduit pipe is produced in nominal 10 ft 3 05 m lengths threaded on each end with one coupling attached. Contact allied tube conduit 16100 south lathrop avenue harvey il 60426 toll free. Pipe conduit specification 1.
L ul 6a l csa 22 2 no. Galvanized rigid steel conduit grc rmc can be used indoors outdoors underground concealed. Specification data rigid steel conduit shall be hot dip galvanized and manufactured by allied tube conduit. Allied tube conduit s galvanized rigid steel conduit is hot dip galvanized for corrosion resistance and is considered non combustible.
The taper of threads is 3 4 inch per foot 1 in 16. 45 2 l ansi c80 5 l nec article 344 l ansi asme b1 20 1. Federal specification ww c 581 class 1 type a has been superseded by ul standard 6 which has been adopted by the federal government.